Safety valves for home gas
Application: The series 670, 676 and 680 gas taps with thermoelectric safety device have been specifically designed to be used in gas ranges.

Safety valves for home gas PDF Print E-mail
{mosimage}{mosimage}{mosimage}

Application: The series 670, 676 and 680 gas taps with thermoelectric safety device have been specifically designed to be used in gas ranges.

 
Construction Characteristics PDF Print E-mail
  • Forged brass body that allows options with and without By-pass.
  • Aluminium alloy cap with firing switch mounting capabilities.
  • Stainless steel spring.
  • Brass stem (6 mm and 8 mm. Diameter).
  • Internal elements resistant to gas corrosion.
 {mosimage}
 
Installation Data PDF Print E-mail
  • Tap to manifold maximun adjusting torque for threaded inlet: 1 Nm.
  • Saddle screws maximun adjusting torque for flanged inlet: 3Nm.
  • Outlet fitting maximun adjusting torque: 15 Nm.
  • Thermocouple maximun adjusting torque: 4 Nm.
 
Performance PDF Print E-mail
  • For all gas types.
  • Maximun inlet gas pressure: 5 Kpa.  (50 mBar)
  • Maximun working temperature: 125 ºC
  • Nominal Flow : 6,2 KW (5300 Kcal./h) for NG; 9,3 KW (8000 Kcal/h) for LPG, measured with air, pressure drop  0,13 Kpa. (13 mm. WC)
  • Minimun flow to be customer specified.
  • Supplied with thermoelectric safety device according to Argentine Standard NAG 318
  • Maximun operating torque: 1 Nm
  • Leakage according to NAG 318.
  • Life test according to NAG 318, NAG 322  and NAG 327
  • Flow adjustment betwen maximun and minimun values
  • Minumun adjusted with By-pas or fixed calibrated orifice.
 