Valves with no safety for home gas |
|
|
|
| {mosimage} | {mosimage} | {mosimage} | | {mosimage} | {mosimage} | {mosimage} | Application: The series 800, 805, 850, 855 and 880 gas taps have been specifically designed to be used in gas ranges. | |
|
Construction Characteristics |
|
|
|
- Forged brass body that allows options with and without By-pass.
- Aluminium alloy cap with firing switch mounting capabilities.
- Stainless steel spring
- Brass stem (6 mm and 8 mm.diameter) with and without axial displacement for firing switch operation
- Internal elements resistant to gas corrosion.
- Gas inlet: threaded or flanged
- Gas outlet: threaded or “fast coupling“
- Inlet/Outlet aligment: 90º or 180º (cook-top design)
| {mosimage} | |
- Tap to manifold maximun adjusting torque for threaded inlet: 1 Nm.
- Saddle screws maximun adjusting torque for flanged inlet: 3Nm.
- Outlet fitting maximun adjusting torque: 15 Nm.
|
- For all gas types.
- Maximun inlet gas pressure: 5 Kpa. (50 mBar)
- Maximun working temperature: 125 ºC
- Nominal Flow : 7 KW (6000 Kcal./h) for NG; 10,5 KW (9000 Kcal/h) for LPG, measured with air, pressure drop 0,13 Kpa. (13 mm. WC)
- Minimun flow to be customer specified.
- Maximun operating torque: 0,20 Nm
- Leakage according to Argentine Standard NAG 327
- Life test according to NAG 327
- Flow adjustment between maximun and minimun values
- Minimun flow adjusted with By-pass or calibrated orifice.
|
|
|
|
|