Safety Valves

Utilización: La Válvula Termostática con seguridad termoeléctrica EITAR modelo 710 B está diseñada especialmente para ser utilizada en hornos de Cocinas Domésticas; el modelo 712 B se utiliza en hornos que también poseen Grill eléctrico; el modelo 716 A en hornos con Grill a Gas y el modelo 715 B está diseñado para Calefactores de Ambiente alimentados a Gas.



Gas taps with thermoelectric safety device for Space Heaters PDF Print E-mail
{mosimage}
{mosimage}
{mosimage}

Use: The series 60, 620, 650 y 900 gas taps with thermoelectric safety device have been specifically designed to be used in any kind of gas space heaters.

 
Manufacturing Characteristics PDF Print E-mail
  • Forged brass body.
  • Series 900 allows options with and without By-pass.
  • Aluminium alloy cap. Optional threaded cap for mounting purposes.
  • Stainless steel spring.
  • Brass stem (6 mm or 8 mm. diameter).
  • Internal elements resistant to gas corrosion.
  • Series 620 and 900 allows different Inlet/Outlets/Mounting fixture configurations.
  • Series 900 allows more functions.
{mosimage}
 
Installation Data PDF Print E-mail
  • Maximum adjusting torque for threaded Inlet/Outlets: 15 Nm.
  • Thermocouple maximum adjusting torque: 4 Nm.
 
Performance PDF Print E-mail
  • For all gas types.
  • Maximum inlet gas pressure: 5 Kpa.  (50 mBar)
  • Maximum working temperature: 125 ºC 
  • -Nominal Flow (measured with air with a 0,13 Kpa. (13 mm. WC) pressure drop) .
    • for series 60:
      • 7 KW (6000 Kcal./h) for NG;
      • 10,5 KW (9000 Kcal/h) for LPG.
    • for series 620:
      • 5,25 KW (4500 Kcal/h) for NG;
      • 7,8 KW (6700 Kcal/h) for GLP.
    • for series 650:
      • 6,2 KW (5300 Kcal/h) for NG;
      • 9,2 KW (8000 Kcal/h) for GLP.
    • for series 900:
      • 6,2 KW (5300 Kcal/h) for NG;
      • 9,2 KW (8000 Kcal/h) for GLP.
    • Minimum flow to be customer specified.
    • Supplied with thermoelectric safety device according to Argentine Standard NAG 318
    • Maximum operating torque: 0,4 Nm (20 ºC)
    • Leakage according to NAG 318.
    • Life test according to NAG 318, NAG 322  and NAG 327
    • Flow adjustment between maximun and minimum valueso
    Aproved by IGA
 


Acceso Directo Institucional

Estadísticas