Thermostats

Utilizacion: Las Válvulas Termostáticas con seguridad termoeléctrica EITAR series 747A, 748A, 751 A, 75113, 752A, 760A y 780A han sido diseñadas especialmente para ser utilizadas en Calentadores de Agua por Acumulación alimentados a gas.



Thermostatic valves with thermoelectric safety device PDF Print E-mail
{mosimage} 

Utilización: The  EITAR Thermostatic valves with thermoelectric safety device have been specifically designed to be used in gas fired storage water heaters.

 
Construction Characteristics PDF Print E-mail
  • Gas resistant internal elements.
  • Body made with an Aluminium Alloy
  • Parts in contact with water made with forged brass and cooper.
  • Gas inlet protected by stainless steel filter.
  • Cooper  sensor according to ASTM B68 and B251.
  • Series 780A is provided with a Temperature Limit (ECO) with automatic reset (thermostat) or one shot (thermal fuse)
  • Cover, knob and push button are plastic made.
  • Colours and markings are customer especified.
 
Installation Data PDF Print E-mail
  • Inlet/Outlet fittings: 3/8” BSP and 3/8” NPT
  • Pilot fitting: W 7/16 x 24 h/”.
  • Sensor Flange Threading: ¾ NPT  or ¾ BSPT
  • Thermocouple connection: M 9x1 o W11/32 x 32 h/”
  • Maximum adjustment torque of the inlet/outlet fittings: 15 Nm.
  • Maximum adjustment torque of the Pilot Burner outlet fitting: 10 Nm.
  • Maximum adjustment torque of the thermocouple: 4 Nm.
 
Performance PDF Print E-mail
  • For any type of gas.
  • Body maximum working temperature: 80 ºC
  • Inlet maximum pressure: 50 HPa (50 mbar)
  • Reference Flow measured with a pressure drop of 1,3 HPa  (1,3 mBar):
    • 18,5 KW ( 15900 Kcal./h) for GN;
    • 28 KW ( 24000 Kcal./h ) for GE.
  • Typical maximum temperature settings: 65 ºC, 70 ºC or  75 ºC (+/- 5ºC)
  • Maximum temperature differential: 11 ºC.
  • Magnetic unit holding time: 5 - 10 s.
  • Magnetic unit releasing time: 30 – 50 s.
  • Temperature Limit operating temperature: from 87 ºC to 95 ºC (optional)
  • Fullfil requirements of the Argentine Standard NAG 314
  • Leakage according to the Argentine Standard NAG 318.
  • Life test according to Argentine Standard NAG 318 y NAG 322.
Aproved by IGA
 


Acceso Directo Institucional

Estadísticas